Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
3.
Dig Endosc ; 2024 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-38433317

RESUMO

OBJECTIVES: Texture and color enhancement imaging (TXI) reportedly improves the identification of the papilla of Vater for selective biliary cannulation compared with white light imaging (WLI). This multicenter study evaluated the efficacy of short-type single-balloon enteroscopy (SBE)-assisted biliary cannulation using a new-generation image-enhanced endoscopy processing system equipped with TXI in patients who underwent Roux-en-Y gastrectomy. METHODS: Patients with Roux-en-Y gastrectomy with a native papilla, and underwent short SBE-assisted biliary cannulation during endoscopic retrograde cholangiopancreatography-related procedures between January 2019 and April 2023 were retrospectively reviewed. Outcomes of biliary cannulation using TXI and WLI were compared. The primary outcome was time to successful biliary cannulation. RESULTS: Thirty-three patients underwent biliary cannulation with TXI and 98 underwent WLI. The biliary cannulation success rates and median time to successful biliary cannulation with TXI and WLI were 93.9% (95% confidence interval [CI] 79.8-99.3%) and 83.7% (95% CI 74.8-90.4%), respectively (P = 0.14), and 10 min (interquartile range [IQR] 2.5-23.5) and 18 min (IQR 9.75-24), respectively (P = 0.04). Biliary cannulation with TXI required a shorter cannulation time than that required with WLI. Adverse event rates with TXI and WLI did not differ significantly (P = 0.58). Multivariate linear regression analysis showed that the use of TXI and short length of oral protrusion were associated with a shorter successful biliary cannulation time. CONCLUSION: Short SBE-assisted biliary cannulation was effective and safe on TXI in patients who underwent Roux-en-Y gastrectomy, and achieved shorter successful biliary cannulation time.

5.
VideoGIE ; 9(3): 137-140, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38482474

RESUMO

Video 1Selective biliary cannulation was difficult, and the catheter tended to be cannulated into the pancreatic duct. We applied a double-wire technique to achieve biliary cannulation. Finally, selective biliary cannulation was achieved. Cholangiography revealed a small stone of approximately 5 mm in the common bile duct (red arrow). Subsequently, endoscopic papillary balloon dilation (EPBD) was performed using a new EPBD catheter with a diameter of 8 mm. This new EPBD catheter was inserted. We inflated this EPBD catheter slightly while observing both endoscopy and fluoroscopy monitors to confirm its dilation process. EPBD was easily and effectively performed without slipping in or out of the papilla. The orifice of the papilla was dilated. Stone extraction was completely achieved.

7.
Clin Endosc ; 57(2): 237-245, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38273220

RESUMO

BACKGROUND/AIMS: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) using Franseen needles is reportedly useful for its high diagnostic yield. This study compared the diagnostic yield and puncturing ability of EUS-TA using 22-gauge cobalt-chromium (CO-Cr) needles with those of stainless-steel Franseen needles in patients with solid pancreatic lesions. METHODS: Outcomes were compared between the 22-gauge Co-Cr Franseen needle (December 2019 to November 2020; group C) and stainless-steel needle (November 2020 to May 2022; group S). RESULTS: A total of 155 patients (group C, 75; group S, 80) were eligible. The diagnostic accuracy was 92.0% in group C and 96.3% in group S with no significant intergroup differences (p=0.32). The rate of change in the operator (from training fellows to experts) was 20.0% (15/75) in group C and 7.5% (6/80) in group S. Stainless-steel Franseen needles showed less inter-operator difference than Co-Cr needles (p=0.03). CONCLUSION: Both Co-Cr and stainless-steel Franseen needles showed high diagnostic ability. Stainless-steel Franseen needles are soft and flexible; therefore, the range of puncture angles can be widely adjusted, making them suitable for training fellows to complete the procedure.

9.
VideoGIE ; 8(7): 269-271, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37456226

RESUMO

Video 1Upon reaching the papilla, fresh blood was observed. However, the bleeding point could not be detected on white-light imaging. Therefore, we switched to texture- and color-enhancement imaging to identify the bleeding point. A visible vessel was identified on texture- and color-enhancement imaging. Endoscopic hemostasis was successfully achieved using a hemostatic clip.

10.
J Transl Med ; 21(1): 398, 2023 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-37337273

RESUMO

BACKGROUND: Myalgic encephalomyelitis/chronic fatigue syndrome/systemic exertion intolerance disease (ME/CFS/SEID) is a condition diagnosed primarily based on clinical symptoms, including prolonged fatigue and post-exertional malaise; however, there is no specific test for the disease. Additionally, diagnosis can be challenging since healthcare professionals may lack sufficient knowledge about the disease. Prior studies have shown that patients with ME/CFS/SEID have low serum acylcarnitine levels, which may serve as a surrogate test for patients suspected of having this disease. This systematic review and meta-analysis aimed to investigate the differences in serum acylcarnitine levels between patients with ME/CFS/SEID and healthy controls. METHODS: This systematic review was conducted using PubMed and Ichushi-Web databases. Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement, we included all studies from the databases' inception until February 17, 2023, that evaluated blood tests in both patients with ME/CFS/SEID and healthy control groups. The primary endpoint was the difference in serum acylcarnitine levels between the two groups. RESULTS: The electronic search identified 276 studies. Among them, seven met the eligibility criteria. The serum acylcarnitine levels were analyzed in 403 patients with ME/CFS/SEID. The patient group had significantly lower serum acylcarnitine levels when compared with the control group, and the statistical heterogeneity was high. CONCLUSION: The patient group had significantly lower serum acylcarnitine levels when compared with the control group. In the future, the measurement of serum acylcarnitine levels, in addition to clinical symptoms, may prove to be a valuable diagnostic tool for this condition.


Assuntos
Síndrome de Fadiga Crônica , Humanos , Biomarcadores/sangue , Estudos de Casos e Controles , Síndrome de Fadiga Crônica/sangue , Síndrome de Fadiga Crônica/diagnóstico
11.
JGH Open ; 7(6): 403-409, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37359117

RESUMO

Scirrhous gastric cancer (SGC) is diagnosed using endoscopy and/or biopsy; however, SGC diagnosis remains challenging owing to its special growth form and morphologic features. Hence, endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), which is minimally invasive and has a high proportion of diagnostic tissue, may be an alternative investigative modality for patients with suspected SGC. This systematic review and meta-analysis aimed to identify and evaluate the evidence for the efficacy and safety of EUS-FNA in patients with suspected SGC. We conducted a systematic review using the PubMed (MEDLINE) and Ichushi-Web (NPO Japan Medical Abstracts Society) databases and included all entries in which SGC was evaluated using EUS-FNA in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement from the databases' inception to October 10, 2022. The primary outcome was the proportion of SGC diagnosed using EUS-FNA. In addition, we analyzed the proportion of adverse events associated with EUS-FNA. The electronic search identified 1890 studies; overall, four studies met the selection criteria and reported data on EUS-FNA performed on 114 patients with suspected SGC. The overall diagnostic yield of EUS-FNA for SGC was 82.6% (95% confidence interval, 74.6-90.6%) and the statistical heterogeneity was 0% (I 2 = 0%), indicating a low heterogeneity. Furthermore, the EUS-FNA diagnostic proportion for SGC lymph node metastasis was 75-100%, indicating a high diagnostic performance. The adverse event rate of EUS-FNA was 0%. EUS-FNA may be an alternative investigation mode for SGC patients with negative esophagogastroduodenoscopy-biopsy results.

12.
Clin Endosc ; 56(6): 716-725, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37070202

RESUMO

Endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered anatomy is technically challenging. For example, scope insertion, selective cannulation, and intended procedures, such as stone extraction or stent placement, can be difficult. Single-balloon enteroscopy (SBE)-assisted ERCP has been used to effectively and safely address these technical issues in clinical practice. However, the small working channel limits its therapeutic potential. To address this shortcoming, a short-type SBE (short SBE) with a working length of 152 cm and a channel of 3.2 mm diameter has recently been introduced. Short SBE facilitates the use of larger accessories to complete certain procedures, such as stone extraction or self-expandable metallic stent placement. Despite the development in the SBE endoscope, various steps have to be overcome to successfully perform such procedure. To improve success, the challenging factors of each procedure must be identified. At the same time, endoscopists need to be mindful of adverse events, such as perforation, which can arise due to adhesions specific to the surgically altered anatomy. This review discussed technical tips regarding SBE-assisted ERCP in patients with surgically altered anatomy to increase success and reduce the risk of adverse events associated with ERCP.

17.
DEN Open ; 3(1): e125, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35898835

RESUMO

Objectives: Understanding the exact morphology of the bile duct opening is important for determining the success of bile duct cannulation. Texture and color enhancement imaging (TXI) has been reported to enhance slight changes in color tone and structure that are difficult to see with white light imaging. This study investigated whether TXI mode1 could improve papillary recognition by trainees inexperienced in endoscopic retrograde cholangiopancreatography. Methods: We included 31 patients with naive papilla of Vater at a single institution in the study. Trainee endoscopists (n = 4) evaluated and identified the papilla according to the Inomata classification using white light imaging and TXI. The degree of agreement with the evaluation of supervising physicians (n = 4) was examined using the McNemar test. Results: In the trainee group, the kappa coefficient agreements were κ = 0.346 and κ = 0.754 for white light imaging and TXI, respectively. When further evaluated, the separate and septal types of papilla groups showed an increased concordance rate in one of the four trainees (76.67%-96.67%, p = 0.031, respectively). Moreover, comparison for two-group evaluation showed an increased kappa coefficient in two of four trainees (0.34-0.92, p = 0.010, 0.45-0.92, p = 0.024). Conclusions: Observation of the duodenal papilla using TXI improved papillary differentiation and suggested the potential of TXI as a clinical tool. Further study of this method is necessary; it is expected to help reduce cannulation time and the incidence of pancreatitis.

18.
DEN Open ; 3(1): e147, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35898843

RESUMO

Objectives: There is no unanimity regarding the most appropriate needle to use for an endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB). To date, new types of FNB needles have been designed, including the Fork-tip and Franseen needles. This study primarily aimed to compare the diagnostic accuracy and histological quality between the use of the Franseen and Fork-tip needles in EUS-FNB for solid pancreatic lesions. Materials and methods: We retrospectively analyzed 147 patients at our center for solid pancreatic lesions, 75 of whom underwent EUS-FNB using a 22-G Franseen needle, and 72 using a 22-G Fork-tip needle, from December 2019 to September 2021. The present study conducted a propensity-matched analysis and confounder adjustment. Results: The diagnostic accuracy of the Fork-tip group (93.3%, 42/45) was the same as that of the Franseen group. For the core tissue and blood scores, no significant difference was observed (p = 0.58, 0.25) between the two groups. The rate of changes in the operator from that of a trainee to an expert was less in the Fork-tip group (4.4%, 2/45) than in the Franseen group (15.6%, 7/45), but not significantly different (p = 0.16). Conclusions: In both groups, the diagnostic accuracy and histological quality were not significantly different. Additionally, there were no significant differences in the rate of operator changes. As both needles are useful, the choice of using either of them is equally good.

19.
Scand J Gastroenterol ; 58(2): 107-115, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35993426

RESUMO

BACKGROUND AND AIMS: Endoscopic retrograde cholangiopancreatography is technically challenging to perform in patients with surgically altered anatomy (SAA). For these patients, endoscopic ultrasound-guided biliary drainage (EUS-BD) is one of the good indications. The aim of our systematic review and meta-analysis was to identify and evaluate evidence of the efficacy and safety of EUS-BD in patients with SAA. METHODS: A systematic review of the PubMed was conducted through to December 2021 to identify studies performing EUS-BD in patients with SAA. The primary outcome was the pooled technical success proportion in patients with SAA. The pooled clinical success and adverse event proportions in patients with SAA were also analyzed. RESULTS: The search identified 1195 possible records, with 18 studies meeting our criteria for analysis, reporting data for 409 patients with SAA who underwent EUS-BD. The pooled technical success, clinical success and adverse event proportions in patients with SAA were 97.8% (95% confidence interval [CI], 95.8-99.7%), 94.9% (95% CI, 91.8-98.1%), and 12.8% (95% CI, 7.4-18.1%), respectively. CONCLUSIONS: EUS-BD is effective for patients with SAA. However, adverse events should be considered when performing EUS-BD in these patients.


Assuntos
Colestase , Humanos , Endossonografia , Colangiopancreatografia Retrógrada Endoscópica , Drenagem/efeitos adversos , Ultrassonografia de Intervenção , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...